Product Introduction
4-68 Series Centrifugal Fan
Product Overview
The 4-68 series centrifugal fan is a high-efficiency, energy-saving, medium-to-low pressure centrifugal ventilation unit. It is widely used for indoor ventilation in factories, mines, tunnels, and large buildings, suitable for both air intake and exhaust applications. This series is designed to transport air and other gases that are non-spontaneous, non-explosive, non-volatile, harmless to humans, and non-corrosive to steel. The gas must be free of sticky substances; dust and hard particle content must not exceed 150 mg/m³, and the gas temperature must not exceed 80°C. The fans are available in left-hand and right-hand rotation configurations, and the discharge outlet angle can be customized to one of six positions ranging from 0° to 270°.
Specifications
This series offers an airflow range of 565–165,908 m³/h, a total pressure range of 294–3,864 Pa, motor power ratings of 0.55–200 kW, and impeller diameters of 200–1,600 mm. The models cover twelve sizes: No. 2.8, 3.15, 3.55, 4, 4.5, 5, 6.3, 8, 10, 12.5, 16, and 20. Four drive configurations are available: Type A (direct motor drive), Type B (belt drive with pulley between bearings), Type C (belt drive with pulley outside bearings), and Type D (coupling drive). Specifically, Type A is used for sizes No. 2.8–5; Type C or D for No. 6.3–12.5; and Type B for No. 16 and 20. Product Materials
Impeller: Features 12 backward-curved airfoil blades welded between a conical shroud and a flat backplate. Constructed from high-quality carbon steel, the impeller undergoes static and dynamic balancing as well as overspeed testing (balancing grade ≤4.0), ensuring excellent aerodynamic performance, high efficiency, and smooth operation. Stainless steel (SUS304) or explosion-proof aluminum impellers are available as options.
Casing: A volute-shaped housing continuously welded from high-quality Q235B carbon steel plate, offering high structural strength and excellent airtightness. Sizes No. 2.8 through 12.5 feature a single-piece casing, while sizes No. 16 and 20 utilize a split-casing design (bolted connection) for ease of maintenance. The surface is treated with spray coating or baked enamel to provide effective rust and corrosion resistance.
Drive Assembly: Comprises the main shaft, bearing housing, rolling bearings, and a pulley or coupling. The main shaft is precision-machined from high-quality 45# carbon steel; the bearing housing features an integrated oil-bath design and is equipped with a thermometer and an oil level gauge.
Functions and Accessories
The 4-68 series fans offer key advantages such as high airflow, low noise, high efficiency, and smooth operation. They can be equipped with accessories like silencers and vibration isolators to minimize operating noise. Optional configurations include: integral base frames, vibration-isolating bases, protective guards, inlet/outlet mating flanges, regulating dampers, electric actuators, diaphragm couplings, soft starters, variable frequency drives (VFDs), temperature sensors, vibration sensors, etc.
Packing List
Depending on the drive method, the standard supply package includes the following:
Drive Type A: One fan unit, one matching three-phase electric motor, and one set of anchor bolts (4 assemblies). Drive Arrangement B/C: Includes one fan unit, one matching three-phase electric motor, one set of motor rails (two pieces), one set of anchor bolts (4 sets for No. 6.3; 8 sets for No. 8 and above), one motor pulley, and one set of V-belts.
Drive Arrangement D: Includes one fan unit, one matching three-phase electric motor, one set of anchor bolts, and one gear coupling assembly.
Products are packaged in standard export-grade wooden crates, complying with the JB/T 6444 general technical specifications for fan packaging.
Usage and Operating Procedures
Step 1: Pre-installation inspection. Conduct a comprehensive inspection of all fan components to ensure parts are intact; verify that the impeller rotation aligns with the casing direction; ensure all connections are tight; confirm that major components (impeller, main shaft, bearings) are free from damage; and ensure the drive assembly operates smoothly.
Step 2: Installation and positioning. Install according to the locations and dimensions specified in the drawings, ensuring that the axial and radial clearances between the inlet and the impeller meet requirements. Mating surfaces between the fan and the foundation, as well as connections to inlet/outlet ducts, must align naturally without forced connection; the weight of the ductwork must not be borne by the fan components.
Step 3: Trial run. Proceed with the trial run only after installation is complete and the final inspection has passed. Start the fan under no-load conditions (with duct dampers closed); once confirmed to be operating normally, gradually open the dampers to reach normal operating conditions. The trial run duration must be at least 2 hours for new installations and at least 30 minutes for units following repair or re-installation.
Step 4: Daily operation. Close the damper before starting and check clearances and rotating parts for any signs of collision or friction. After starting and reaching normal operating speed, gradually open the damper to the specified load. During operation, strictly ensure the current does not exceed the motor's rated value, regularly check the responsiveness of thermometers and oil level indicators, and maintain the bearing housing oil level within the specified range. Warranty Policy
This product comes with a 12-month warranty starting from the date of manufacture. During the warranty period, free repair or replacement services are provided for malfunctions caused by defects in design, workmanship, or materials. Beyond the warranty period, we offer lifetime technical support and discounted spare parts. Our national service hotline is available to respond to inquiries and provide on-site installation, maintenance, and non-standard customization services.
Application Scenarios
The 4-68 series centrifugal fans are widely used in the following applications: indoor ventilation for general factories and large buildings; exhaust and dust removal in industrial plants; forced draft and induced draft for boilers and industrial furnaces; exhaust systems for automotive spray booths; dust removal in the electronics industry; blast air supply in the steel industry; and dust collection and waste gas treatment in sectors such as chemicals, building materials, and mechanical processing. In thermal power plants, the GY4-68 centrifugal fan is suitable for forced and induced draft applications with steam boilers rated below 230 t/h.
Real-World Cases
Case 1: China Salt Anhui Hongsifang Co., Ltd. The company purchased 4-68 No. 4.5A centrifugal fans for its soda ash and West Zone O&M workshops. Specifications included an airflow of 6,573–8,920 m³/h, total pressure of 2,626–2,295 Pa, 7.5 kW power, and a 90° clockwise rotation. The units included mounting brackets and vibration-damping pads and were equipped with Grade 1 energy-efficiency motors for use in workshop ventilation and dust removal systems.
Case 2: China Salt Qinghai Kunlun Soda Industry Co., Ltd. The company purchased 4-68 series centrifugal fans (equipped with 22 kW high-altitude motors) with an airflow of 12,600 m³/h and a speed of 2,900 r/min. These were applied to the dust collector system in the soda ash production workshop, effectively improving air quality in the high-altitude environment.
Case 3: Anhui Jinyan Kaolin New Materials Co., Ltd. For its deep-processing project involving mullite-based aluminum-silicon materials, the company selected the 4-68 No. 6.3C centrifugal fan—featuring an airflow of 12,852 m³/h, a total pressure of 3,159 Pa, and a rotational speed of 2,240 r/min—to handle material drying and process ventilation.
With its proven design, reliable performance, and broad applicability, the 4-68 series centrifugal fan has established itself as a trusted, classic product in the field of industrial ventilation and dust removal. Please contact us for model selection advice or non-standard customization to receive a professional solution.