FB Series Axial-Flow Auxiliary Mine Fan
Product Overview
The FB Series Axial-Flow Auxiliary Mine Fans are high-efficiency ventilation units specifically designed for underground coal mine environments where explosive gases, such as methane (firedamp), may be present.
Featuring an aerodynamic design with airfoil-shaped blades and an explosion-proof construction, these fans offer a safe, reliable, and durable solution. They are characterized by low noise, high efficiency, low energy consumption, and the capability for long-distance air delivery. They effectively meet the quantitative ventilation requirements for mine heading faces and maintain stable, efficient operation across a wide range of working conditions.
FB series axial-flow auxiliary mine fans are widely used for ventilation in coal mines, metal and chemical mines, tunnel construction, and the metallurgical and building materials industries. They are an ideal choice for underground forced (positive-pressure) auxiliary ventilation.
Operating Principle
When the impeller of an FB series axial-flow auxiliary mine fan is driven by the electric motor, it rotates at high speed. The blades perform work on the surrounding air, imparting a rotational velocity (swirl) to the airflow in the same direction as the impeller's rotation.
The unit is equipped with guide vanes that introduce a pre-rotation (swirl) in the opposite direction to the impeller's rotation as the air passes through. This pre-rotation cancels out the swirl induced by the blades, resulting in a uniform axial airflow, which enables the fan to achieve high operational efficiency.
In models featuring a dual-impeller design, the two impellers are arranged to rotate in opposite directions. This configuration provides two-stage pressurization and airflow rectification, further increasing the pressure coefficient and extending the air delivery distance.
Key Features
Safety and Explosion-Proof Design: The entire unit features an explosion-proof construction (rated ExdbⅠMb) and is equipped with a YBF3 series explosion-proof, three-phase asynchronous motor. It is suitable for use in underground coal mine environments containing explosive gases like methane. The product complies with the MT/T 222-2019 standard, "Technical Conditions for Auxiliary Fans Used in Coal Mines," and must carry the "MA" (Mine Safety) certification mark before it can be deployed underground.
High Efficiency and Energy Conservation: Utilizing high-efficiency axial-flow blades, these fans deliver excellent aerodynamic performance and long-range air supply. They combine low energy consumption with high efficiency, ensuring stable operation even at low flow rates, which effectively reduces operational costs. The fan blades utilize the FMIA airfoil profile—a design derived from aero-engine technology. Through multi-objective, holistic optimization using computational fluid dynamics (CFD), the fan achieves a broad, high-efficiency operating range.
Low noise and long service life. A unique noise-attenuation structure ensures quiet operation and low maintenance costs. The unit is designed for a service life of at least 5 years, with an operational reliability of over 13,000 hours before the first major overhaul. Multi-stage silencing and rubber vibration-damping mounts keep noise levels below 84 dB(A).
Reliable operation. The unit features a simple, robust installation base, ensuring stable and dependable performance across various underground environments. Its direct-drive configuration eliminates issues such as belt wear or slippage; routine maintenance is limited to periodic lubrication of the bearings, resulting in a low failure rate.
Technical Parameters
| Impeller Diameter |
Electric Motor Power |
Air Volume |
Pressure |
| 300mm |
1.5kW |
0.9m³/s~1.4m³/s |
928Pa~575Pa |
| 400mm |
5.5kW |
2.2m³/s~3.5m³/s |
1648Pa~1020Pa |
| 400mm |
11kW |
2.2m³/s~3.5m³/s |
2923Pa~1811Pa |
| 450mm |
11kW |
3.0m³/s~5.2m³/s |
2276Pa~1275Pa |
| 650mm |
11kW |
7.1m³/s~8.4m³/s |
884Pa~665Pa |
| 750mm |
22kW |
10.9m³/s~12.9m³/s |
1177Pa~883Pa |
| 800mm |
30kW |
13.2m³/s~15.6m³/s |
1339Pa~1005Pa |
Structural Composition
The FB series ventilation fan consists primarily of an inlet cone (collector), the main unit, an electric motor, an impeller, and a diffuser. Depending on the model, the unit may feature a single-impeller or dual-impeller (two-stage) configuration—the latter designed to increase both pressure and airflow. The overall design is compact, facilitating easy installation and maintenance. The unit is constructed from thick, welded steel plate, providing high resistance to impact and moisture. The inlet protective screen channels airflow while preventing debris from entering and damaging the impeller. Sound-absorbing material is integrated into the front and rear silencer sections. The explosion-proof motor is directly coupled to the impeller, eliminating vulnerable components like belts or gears. The diffuser outlet connects to flexible ventilation ducting, stabilizing pressure and directing airflow. The explosion-proof terminal box features a sealed, flameproof design, preventing any electrical sparks from escaping and potentially igniting mine gas or coal dust.
Application Scenarios
The FB series mining-duty auxiliary (local) fan is primarily designed for use in the intake roadways of underground coal mines, operating in conjunction with positive-pressure ventilation ducting to provide forced (pressurized) local ventilation. It is also widely used in metal mines, chemical mines, tunnel construction, underground engineering projects, industrial facilities, and environmental dust-control systems. The equipment is suitable for applications such as mine heading (excavation), shaft sinking, local ventilation, and long-distance tunnel ventilation across coal mines, metal and non-metal mines, and various other industrial and mining operations. Selection Guidelines
When selecting equipment, users should consider parameters such as the length and cross-sectional area of the heading (excavation roadway), gas emission levels, and the required airflow volume and pressure. For short roadways (under 200 meters), a single-stage FB-series fan is recommended, as it features a lightweight design and is cost-effective. For medium-to-long roadways (600–2,000 meters), a dual-impeller FB-series model is advised to achieve higher air pressure and a greater air delivery distance.
Please feel free to contact us for detailed technical specifications or product pricing regarding our FB-series mine auxiliary (local) fans.