The FBD series mine counter-rotating axial-flow auxiliary fan is a core piece of equipment for ventilation systems serving underground coal mine headings and various other underground engineering projects.

Designed and manufactured in accordance with industry standard MT/T 222, this series features an explosion-proof rating of Exd I Mb. It operates safely in intake airflows with methane concentrations below 1%, delivering fresh air to the working face via positive-pressure ducting to effectively dilute methane, coal dust, and blasting fumes.

Counter-Rotating Principle and Key Advantages

The FBD series utilizes a two-stage counter-rotating structure, where two explosion-proof motors of identical specifications drive the first- and second-stage impellers to rotate at the same speed but in opposite directions. Air enters the first-stage impeller axially from the inlet cone, gains kinetic energy, and then flows directly into the second-stage impeller for further pressurization.

While boosting airflow energy, the second-stage impeller also performs the function of the stationary guide vanes found in traditional axial fans; it straightens the airflow and reduces friction noise, thereby achieving higher air pressure and efficiency compared to single-stage axial fans.

This design offers multiple performance advantages. Long-distance air delivery is a standout feature of the FBD series; the two-stage pressurization ensures ample air pressure, allowing for effective ventilation in roadways up to 2,000 meters long without the need to relocate the fan mid-way, which significantly reduces labor intensity and the time required for ventilation operations.

Energy efficiency is remarkable; the counter-rotating structure minimizes energy losses associated with guide vane assemblies, achieving an aerodynamic efficiency of over 80%—a saving of more than 20% in electricity consumption compared to older single-stage auxiliary fans. Additionally, for shorter roadways, the system can switch to single-motor operation to further reduce power consumption.

Regarding noise control, the unit employs an encapsulated dual-layer silencing structure and a silencer casing filled with flame-retardant sound-absorbing material. Noise levels are kept below 85 dB(A)—with the noise level not exceeding the ambient background noise by more than 25 dB—significantly improving the acoustic environment for underground operations. Furthermore, the unit offers robust operational stability and a smooth pressure-flow curve; it is resistant to surging and airflow failure in low-flow, high-pressure operating zones, making it highly adaptable to complex roadway conditions.

Product Specifications Table

Impeller diameter (mm) Electric motor power (kW) Air volume (m³/min) Pressure (Pa)
500 2×7.5 266~178 400~3155
560 2×11 324~215 375~3690
630 2×30 518~318 640~7310
710 2×45 696~402 686~8161
800 2×75 970~560 850~9950

Selection Guide

Selection should be based on a comprehensive assessment of factors such as the length and cross-sectional area of ​​the heading, required airflow, and ventilation resistance. Recommended selection criteria are as follows: for short-distance roadways (under 200 meters), the FBD No. 4.0 or No. 5.6 series of small fans is suitable, with single-motor operation sufficient to meet requirements.

For standard heading distances (300 to 1,200 meters), the FBD No. 6.0 and No. 6.3 models are recommended; these offer flexible power configurations (ranging from 2×11 kW to 2×22 kW) and represent the most widely used specifications in underground coal mining.

For long-distance headings (1,200 to 2,000 meters), the FBD No. 7.1 or No. 8.0 series is advised. With power ratings ranging from 2×30 kW to 2×75 kW, these models provide the higher total pressure necessary to overcome duct friction losses.

The unit’s structure comprises an inlet cone, primary and secondary casings, two explosion-proof motors, two-stage impellers, an outlet silencer, and duct connectors. It features a modular casing design, facilitating transport, installation, and maintenance within the confined spaces of underground roadways. Direct motor drive eliminates the need for belts, gears, or other wear-prone components, resulting in lower operation and maintenance costs.

Operating Conditions and Maintenance

The FBD series fans are designed for operating environments with gas temperatures between -20°C and 40°C and altitudes not exceeding 1,000 meters; the dust concentration of the conveyed gas must not exceed 200 mg/m³. The fan can be placed directly on the roadway floor or suspended from the roadway wall using top-mounted lifting lugs; when floor-mounted, the inlet end must not be submerged in water or mud.

To ensure long-term, stable operation, maintenance must be performed at the prescribed intervals. Bearings should be inspected at least once every 2,500 hours of operation (approximately every six months). If the grease has deteriorated, it must be replaced promptly; ZL-3 lithium-based grease is recommended, with a fill volume equal to half the free space in the bearing housing. Mixing different brands of grease is strictly prohibited.

If noise levels increase due to dust clogging the silencer orifice plate, the plate must be cleaned using compressed air; spraying with water is strictly prohibited to avoid compromising the performance of the sound-dampening material.

Initial maintenance should be performed after three months of fan operation, involving checks on the motor status, replenishing lubricant, removing coal dust, and verifying the clearance between the impeller and the casing. Care must be taken to protect the flameproof surfaces during motor disassembly and reassembly; 204-1 anti-rust oil should be applied during assembly. These surfaces must be free of damage or corrosion, as any defects would compromise the unit's overall flameproof integrity.

Direction of Intelligent Ventilation Upgrades

With the advancement of intelligent coal mine construction, the FBD series of mining flameproof contra-rotating axial-flow auxiliary fans has evolved into a complete intelligent variable-frequency system.

This system comprises the FBDY series mining auxiliary fan, a mining flameproof and intrinsically safe variable-frequency drive (VFD), a programmable control box, and various sensors. Utilizing variable-frequency speed regulation and PLC control technologies, the system offers features such as remote control, online monitoring, automatic airflow adjustment, threshold alarms, and automatic fan switching.

The system automatically adjusts fan speed based on real-time fluctuations in gas concentration at the heading face. This enables on-demand airflow supply while maintaining safe ventilation levels, thereby further reducing energy consumption. This intelligent upgrade transforms the FBD series from a standalone ventilation unit into a comprehensive ventilation system solution that integrates safety monitoring with energy-saving control.

With their efficient contra-rotating pressure-boosting design, reliable flameproof safety performance, and flexible model configurations, the FBD series of mining contra-rotating axial-flow auxiliary fans continues to provide proven technical support for ventilation in coal mines and underground excavation projects. Whether for conventional forced-air ventilation or intelligent variable-frequency ventilation systems, this product series allows for targeted selection and configuration based on specific operating conditions.

Technical Team

Our technical team has been deeply engaged in the fan industry for 30 years and possesses extensive technical expertise.

Quality Control

Our company s production and inspection processes adhere to the ISO 9001 quality management system.
ADDRESS

ADDRESS

Industrial Park, Nanjiao Town, Zhoucun District, Zibo City, China
EMAIL

EMAIL

sales@kaiyuefans.com
PHONE

PHONE

+86 15105330566

Get A Quote

We will reply to you within three hours of receiving your message.
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.
Leave a message
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.