• FCZ Series Mine Axial Fan

Product Introduction

FCZ Series Mine Axial Fan


Product Overview

The FCZ Series Mine Axial Fan is a high-efficiency, energy-saving ventilation unit designed specifically for large-scale mine ventilation systems. It features a long-shaft structure with adjustable rotor blades and an externally mounted motor.

Developed using 3D flow design theory and CFD (Computational Fluid Dynamics) analysis, the fan boasts an impeller with superior aerodynamic characteristics, achieving a total pressure efficiency of up to 90%. The FCZ series is widely used in the main ventilation systems of coal, metal, and non-metal mines. It also serves industrial sectors such as sintering dust removal and flue gas desulfurization (FGD) boosting systems in the iron and steel industry, as well as boiler forced-draft and induced-draft systems in power generation.

Working Principle

The core technical advantage of the FCZ series lies in its adjustable rotor blade mechanism. A hydraulic cylinder control system adjusts the working angle of the impeller blades in real-time, shifting the fan's performance curve to meet operational demands. This ensures high-efficiency operation even as airflow and pressure requirements fluctuate.

The blade angle adjustment range is 30° to 85°, covering 20% ​​to 110% of the design performance range. The key value of this adjustable rotor blade technology is that—when there is a significant difference in network resistance between "easy" and "difficult" ventilation periods—the fan can dynamically match operating points simply by adjusting the blade angle, without the need to replace the impeller or change the rotational speed. This allows the equipment to operate within its high-efficiency zone across different ventilation stages. This characteristic makes the FCZ series particularly suitable for mines where ventilation network resistance changes continuously as mining depth increases and roadways extend.

Core Technical Features

High-efficiency, wide-range adjustment capability. The FCZ series utilizes hydraulic cylinders to control impeller blade angles, offering a broad adjustment range and stable operation under varying conditions; it maintains high efficiency across the 20% to 110% design performance range. Compared to fans with fixed blades or adjustable stator vanes, the adjustable rotor blade design offers significant energy savings under variable operating conditions, making it especially ideal for projects with large disparities in pressure requirements between easy and difficult ventilation periods.

Long service life and low maintenance costs. This series of fans utilizes a forced-oil lubrication system (via a thin-oil station) and air cooling; bearing temperature rise is controlled within 35°C, ensuring a bearing service life of at least 80,000 hours. The blades are made of forged aluminum alloy, and the hub is constructed from forged low-pressure alloy steel, offering excellent structural strength and fatigue resistance. The equipment boasts an annual utilization rate exceeding 99%, requires a major overhaul only once every four years, and remains completely maintenance-free for the first five years, significantly reducing downtime and maintenance costs for mining operations.

Low vibration and low noise. Operational vibration levels are kept below 2.5 mm/s, and noise levels do not exceed 85 dB(A), complying with the noise limit requirements for underground workplaces specified in the *Code for Design of Noise Control for Industrial Enterprises*. This feature is of practical significance for improving the underground working environment and safeguarding the occupational health of personnel.

Intelligent and automated integration. The FCZ series fans can be equipped with online monitoring and fault diagnosis systems. Combined with variable frequency drives (VFDs) and coordinated control of vertical dampers, they enable one-touch startup, fan switching without interrupting airflow, and unattended operation. In the context of smart mine development, this series integrates seamlessly with centralized control systems for main mine ventilation stations, supporting remote operational monitoring, fault early warning, and energy efficiency analysis.

Key Technical Parameter Ranges

The FCZ series encompasses a wide range of specifications and models to meet the ventilation needs of mines of various sizes. Maximum airflow reaches 1,100 m³/s, maximum static pressure reaches 21,000 Pa, and the fan features 16 blades. Motor configurations are flexible, allowing for the selection of brands such as Jiamusi, Innomotics, Nanyang Explosion-proof, SEC (Shanghai Electric), and ABB; bearings are sourced from international brands like SKF and NSK, and the cooling method is oil cooling. During actual model selection, the required airflow and negative pressure are calculated based on the mine ventilation network. The most suitable model is then customized by adjusting parameters such as impeller diameter, hub ratio, and operating speed. This ensures the fan operates within a high-efficiency, stable range during both "easy" and "difficult" ventilation periods, while maintaining the required performance margins.

Typical Application Scenarios

The FCZ series mine axial-flow fans are primarily used in the following scenarios:

Coal Mine Main Ventilation Systems: Serving as the mine's main fan, the unit handles ventilation for the entire mine or specific zones. A typical case involves a mine's return-air inclined shaft utilizing two FCZ-2240/1400 axial-flow fans (one duty, one standby) powered by 990 rpm, 6 kV, 630 kW AC motors. Stepless operational adjustment is achieved through dynamic blade pitch control. Motor reserve coefficients are 1.57 for easy ventilation periods and 1.27 for difficult periods, both meeting regulatory standards.

Deep Metal Mine Ventilation: In deep-mining operations, FCZ long-shaft axial-flow fans utilize an external motor configuration. Two fans operate in parallel at each level to meet requirements for high negative pressure and long-distance ventilation. One gold mine project utilized FCZ fans, achieving an airflow of 283.4 m³/s and negative pressure of 4,465 Pa at the -1,200 m level, and 321.4 m³/s and 4,671 Pa at the -1,320 m level; fan efficiency at these operating points remained at or above 85%.

Zonal Ventilation with Multiple Shafts: For mines undergoing renovation or expansion that utilize zonal ventilation, the FCZ series can serve as the main fan for a secondary ventilation shaft, complementing counter-rotating axial-flow fans. Mine Shaft No. 2 is equipped with two FCZ-Ne22.5/500 (II) type ventilators, featuring a rated airflow of 1,600–7,450 m³/min, a rated pressure of 400–2,850 Pa, and a motor power of 500 kW, effectively meeting the differentiated requirements of zonal ventilation.

Selection Criteria

The selection of FCZ-series mine axial-flow ventilators should focus on the following aspects:

Matching Airflow and Pressure. Determine the required airflow and negative pressure based on mine ventilation network calculations. Account for external air leakage coefficients (typically 1.05) as well as the impact of natural ventilation pressure and altitude on air density. Suppliers must provide verification calculations confirming that operating efficiency under specified conditions is no less than 80%.

Verification of Blade Adjustment Range. During selection, confirm that blade installation angles for both "easy" and "difficult" ventilation periods fall within the equipment's permissible range and allow for an adjustment margin of at least 5°, in compliance with the *Code for Design of Main Ventilator Stations in Coal Mines*.

Motor Configuration. Prioritize the use of variable-frequency drive (VFD) motors suitable for mining applications to facilitate stepless airflow regulation and energy-efficient operation. Motor power must ensure an adequate reserve coefficient; for difficult ventilation periods, this coefficient should generally be no less than 1.2.

Explosion-Proofing and Safety Certification. FCZ ventilators intended for underground coal mines or environments with risks of gas or coal dust explosions must hold a Safety Mark Certificate for Mining Products (MA certification). Electrical components requiring explosion protection must possess an explosion-proof conformity certificate issued by a national inspection authority. Core motor components must independently hold both a Class I explosion-proof conformity certificate and a Safety Mark Certificate for Mining Products.

Certifications and Standards

The design, manufacturing, and inspection of FCZ-series mine axial-flow ventilators comply with various national and industry standards. Key reference standards include "Technical Specifications for Axial-flow Main Mine Fans" (GB/T 21151-2007), "Safety Inspection and Testing Specifications for Main Mine Fan Systems in Use" (AQ 1011-2005), and "Safety Inspection and Testing Specifications for Mine Products in Use: Main Mine Fan Systems" (MT/T 1205-2023). The product must obtain the National Safety Mark Certification for Mining Products and comply with the relevant requirements of the "Safety Regulations for Metal and Non-metal Mines." When purchasing, users should require suppliers to provide valid qualification documents, such as the MA (Mining Product Safety Mark) certificate, explosion-proof conformity certificate, and factory inspection report.

Technical Team

Our technical team has been deeply engaged in the fan industry for 30 years and possesses extensive technical expertise.

Quality Control

Our company s production and inspection processes adhere to the ISO 9001 quality management system.
ADDRESS

ADDRESS

Industrial Park, Nanjiao Town, Zhoucun District, Zibo City, China
EMAIL

EMAIL

sales@kaiyuefans.com
PHONE

PHONE

+86 15105330566

Get A Quote

We will reply to you within three hours of receiving your message.
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.
Leave a message
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.