• FKZ Series Mine Axial-Flow Fan

Product Introduction

FKZ Series Mine Axial-Flow Fan

Product Overview

The FKZ series mine axial-flow fan represents a new generation of high-efficiency mine ventilation equipment, developed through technical improvements, structural optimization, and an expanded range of model sizes.

Featuring an integrated design where the motor is directly coupled to the impeller, this series offers high aerodynamic efficiency, low operating noise, and a compact, stable structure. It is specifically designed to meet the ventilation needs of various non-coal mines, including those in the metallurgical, non-ferrous metal, chemical, building materials, and nuclear industries.

The FKZ series covers a wide range of impeller diameters and offers two hub-to-tip ratios (0.40 and 0.45), resulting in over 60 model specifications. This comprehensive product family ensures optimal matching with mine ventilation networks across diverse resistance and airflow requirements.

These fans can serve as either main fans or auxiliary fans within multi-fan series/parallel or multi-stage ventilation systems, and are suitable for installation either on the surface or underground.



Working Principle

The FKZ series fan utilizes an axial-flow structure. Airflow enters the main unit axially from the inlet cone (collector) end, is accelerated by the impeller, and is discharged axially from the diffuser end. As the impeller rotates, gas enters axially, gains energy through the pushing action of the blades, and then flows into the guide vanes; the guide vanes redirect the deflected airflow into axial flow, thereby achieving efficient and stable ventilation.

The fan assembly consists of major components including the inlet cone, main housing, motor, diffuser, and an electrical control system (with an optional variable frequency drive).

Technical Features and Key Advantages

High-Efficiency Aerodynamic Design: The fan employs large-chord, twisted airfoil blades, delivering high aerodynamic efficiency and significant energy savings. The blade installation angle can be adjusted to accommodate changes in mine production, offering flexibility for various operating conditions.

Direct-Drive Structure: The motor and impeller are directly coupled, ensuring excellent overall stability, ease of installation, and simplified maintenance. Compared to belt or long-shaft drive systems, the direct-drive configuration offers higher transmission efficiency, eliminates risks associated with transmission failures or shaft breakage, and ensures uninterrupted operation even in the event of minor foundation settlement or shifting.

Anti-Surge Flow-Stabilizing Ring: The main fan casing is equipped with a flow-stabilizing ring that eliminates the "hump" in the fan characteristic curve. This removes the risk of surging and ensures safe, stable operation across all resistance levels—making it particularly suitable for complex ventilation systems involving multiple fans operating in parallel.

High-Strength, Durable Design: The fan body features a welded structure made of steel plate and structural steel sections, while the blades are constructed from hollow steel plate. The unit offers exceptional structural strength and resistance to underground blast shockwaves, enabling long-term operation in humid underground environments.

Reversible Airflow Capability: The fan supports reverse rotation for airflow reversal, achieving a reversal rate exceeding 40%. This eliminates the need for dedicated air-reversal ducts, thereby effectively reducing civil engineering requirements and investment costs.

Low-Noise Operation: Optimized aerodynamic design and the direct-drive configuration effectively control operating noise, improving the acoustic environment for mine operations.

Key Technical Parameters

The FKZ series fans offer an airflow range of 2.0 m³/s to 164.2 m³/s, a total pressure range of 38 Pa to 2409 Pa, and motor power ratings from 1.1 kW to 250 kW, meeting a wide range of ventilation needs for non-coal mines, from small to large-scale operations. VI. Normal Operating Conditions
The FKZ series fans are suitable for the following environmental conditions:

Altitude not exceeding 1,000 m

Operating temperature range: -20°C to +40°C

Relative humidity: ≤95% RH (at +25°C)

The conveyed medium must not contain explosive gases such as methane.

Safety Standards and Certifications

The FKZ series fans strictly adhere to relevant national and industry standards for mining ventilation equipment. Key technical specifications include GB/T 21151-2025 "Technical Specifications for Axial-flow Main Fans for Coal Mines" and industry standards such as MT/T 222-2019. Explosion-proof models also comply with the GB3836 series of explosion-proof standards, ensuring safe and reliable operation in underground mining environments.

Application Scenarios

FKZ series axial-flow mining fans are widely used in various non-coal mines—including those for metallurgy, non-ferrous metals, gold, chemicals, building materials, and the nuclear industry. They can serve as main or auxiliary mine fans and be installed either on the surface or underground. They are particularly well-suited for use as fans at various stages within multi-fan ventilation systems employing series, parallel, or multi-stage station configurations.

Additionally, this series is suitable for ventilation in large workshops, tunnel projects, and civil air defense facilities, demonstrating broad adaptability to various operating conditions. In recent years, continuous advancements in underground ventilation technology for non-coal mines—and the successful deployment of ultra-high-power underground axial-flow fans—have further validated the critical role of axial-flow fans within complex mine ventilation networks.

Maintenance Highlights and Service Life

The FKZ series fans have a design service life of 15 years, with a safe operating duration of over 12,000 hours before the first major overhaul.

Routine maintenance should focus on the following:

Regularly check the lubrication status of the bearings (approximately every 2,500 hours of operation). Use ZL-3 lithium-based grease, filling the bearing housing to half its net capacity; strictly avoid mixing different brands or types of grease. If the silencer becomes clogged with dust, resulting in increased noise, it should be cleaned by flushing with compressed air; washing with water is strictly prohibited.

The ventilator must be managed and operated by a dedicated or part-time operator. Part-time operators must verify normal operation 10 minutes after startup and continuously monitor the ventilator's running status.

For equipment stored for more than six months, the bearing grease must be replaced before use; for equipment stored for more than three months, additional grease must be applied before use.

Model Selection and Customization

FKZ series ventilators can be selected and matched based on a mine's specific ventilation network parameters, resistance characteristics, and airflow requirements. By combining two hub ratios (0.40 and 0.45) with three motor speeds (4-pole, 6-pole, and 8-pole), over 60 model specifications are available, ensuring users can select the optimal unit that operates within its high-efficiency range.

To meet the unique needs of different mines, customization services—such as the choice of blade materials (hollow steel blades or high-strength cast/forged aluminum blades) and electrical control system configurations (including variable-frequency drive options)—are available, helping mines achieve the dual goals of energy conservation and safe ventilation.

Technical Team

Our technical team has been deeply engaged in the fan industry for 30 years and possesses extensive technical expertise.

Quality Control

Our company s production and inspection processes adhere to the ISO 9001 quality management system.
ADDRESS

ADDRESS

Industrial Park, Nanjiao Town, Zhoucun District, Zibo City, China
EMAIL

EMAIL

sales@kaiyuefans.com
PHONE

PHONE

+86 15105330566

Get A Quote

We will reply to you within three hours of receiving your message.
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.
Leave a message
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.