• Power Plants Secondary Air Fan

Product Introduction

Power Plants Secondary Air Fan


Secondary air fans are critical air-supply components within the flue gas and air systems of circulating fluidized bed (CFB) boilers and coal-fired power units. Their primary functions include delivering heated air to the furnace in a staged manner, regulating oxygen levels in the flue gas, controlling bed temperature, and suppressing the formation of nitrogen oxides (NOx). In CFB boilers, the secondary air fan operates in coordination with the primary air fan, induced draft fan, and high-pressure fluidizing air fan; its operational reliability directly impacts the boiler's combustion efficiency, environmental emissions, and the overall availability of the power unit.

The Role of Secondary Air Fans in Power Plant Boilers

While the primary air fan is primarily responsible for fluidizing bed material and supplying air for combustion in the dense-phase zone, the secondary air fan targets the suspension section and the dilute-phase zone in the upper and middle parts of the furnace. By introducing secondary air in a staged, layered manner, the system not only provides the additional oxygen required for combustion but also creates a localized reducing atmosphere above the dense-phase zone, which inhibits the formation of nitrogen oxides. This "staged air supply" logic means that the secondary air fan serves not merely as a mechanical air-moving device, but as an essential component in the boiler’s low-NOx combustion strategy.

In 300 MW-class CFB boilers, secondary air fans are typically configured as standalone units—usually high-pressure centrifugal fans—with airflow regulated via inlet dampers or by adjusting the motor speed. As unit capacities increase and the requirements for deep load-peaking (flexible operation) grow, the control precision and part-load efficiency of these fans have an increasingly significant impact on the plant's auxiliary power consumption.

Operating Principle and Equipment Selection

Secondary air fans are categorized as air-supply equipment, handling air (either at ambient temperature or preheated). In a centrifugal secondary air fan, the motor drives the rotation of an impeller. Centrifugal force propels the air between the impeller blades toward the casing (volute) walls, from where it is discharged through the outlet. A negative pressure zone is created at the center of the impeller, drawing in fresh air from the outside under atmospheric pressure, thereby ensuring a continuous supply of air. In power plants, secondary air fans are predominantly of the centrifugal type. This is because the dense-phase zone of a circulating fluidized bed (CFB) boiler furnace operates at a relatively high positive pressure, requiring the secondary air fan to provide sufficient head to deliver air into the furnace at the designated locations. Common centrifugal configurations include single-inlet, single-stage, dual-bearing designs; double-inlet designs; and dual-stage impeller arrangements. For applications requiring high airflow and high pressure, a dual-stage impeller design can deliver stable, high-pressure air within a more compact footprint, while also improving rotor dynamic characteristics. Some 300 MW-class CFB boilers utilize dual-stage, variable-pitch axial-flow fans, which offer a broader range of regulation; however, centrifugal fans remain superior in terms of wear resistance and maintainability when operating under high-pressure and dust-laden conditions.

Key Design Considerations for Power Plant Applications

Impeller Wear Resistance: The Critical Factor for Fan Service Life

Secondary air fans continuously handle dust-laden air, subjecting the blades—particularly the leading edges at the inlet and the areas near the center disc—to persistent erosion by solid particles. Standard blades may require replacement within just a few years under high-dust conditions. Given the limited maintenance windows in power plants, wear-resistant design is directly linked to the total lifecycle cost.

Common strategies include: hard-facing high-wear areas of the blades with hard alloys, which significantly increases surface hardness and can more than double the service life compared to standard blades; installing wear-resistant strips or protective caps on the blade leading edges to act as sacrificial elements, thereby shielding the base material; and utilizing low-alloy steels (such as 16Mn) subjected to rigorous heat treatment to achieve an optimal balance of strength, weldability, and inherent wear resistance. In environments where wear is particularly severe, further enhancements—such as the use of composite wear-resistant steel plates or ceramic liners—may be employed.

Temperature Resistance and Material Compatibility

The inlet air temperature for secondary air fans is typically moderate (ranging from ambient temperature up to approximately 80°C). However, in scenarios where air is supplied downstream of an air preheater, or in specific boiler configurations, the operating temperature may be significantly higher. The materials for the impeller and casing must be selected based on the actual temperature profile. For standard operating conditions, high-quality carbon steel or 16Mn steel may be used. For medium-to-high temperature ranges, low-alloy heat-resistant steel plates (such as 15CrMo or 12Cr1MoV, suitable for temperatures up to approximately 540°C) are appropriate. In cases involving even higher temperatures or the presence of corrosive components, heat-resistant stainless steel or duplex stainless steel should be employed. The main shaft is typically fabricated from 45# high-quality carbon steel or alloy structural steel, while the bearing housing and sealing arrangements must be designed to effectively prevent dust ingress and oil leakage.

Regulation Methods and Energy-Efficient Operation

The method used to regulate the airflow of a secondary air fan directly impacts energy efficiency during partial-load operation. Traditional inlet damper regulation results in significant throttling losses at low loads. Transitioning to variable-frequency drive (VFD) speed control—where the inlet damper is kept fully open and the motor speed is adjusted to match load demand—can substantially reduce both throttling losses and high-speed pressure losses. For power generation units involved in deep peak-shaving, VFD retrofitting also helps mitigate the stress placed on the motor and the auxiliary power system by frequent start-stop cycles. Defining the regulation strategy during the equipment selection phase facilitates the inclusion of VFD interfaces and ensures a design with a broad high-efficiency operating range.

Typical Technical Parameters

The parameters for secondary air fans in power plants vary significantly, depending on boiler capacity, furnace pressure regimes, and the design of the air supply system. The following is an example of an engineering configuration, provided as a reference for the equipment selection phase:

High-pressure, high-capacity configuration: T9-28 No. 20.3F; inlet flow rate approximately 206,520 m³/h; total pressure 16,800 Pa; shaft power 1,300 kW; main shaft speed 1,450 r/min; equipped with a 1,600 kW/10 kV motor; featuring a single-suction, single-stage, dual-support design. Medium-capacity configuration: 9-28 № 13.8D; flow rate approximately 84,622 m³/h; total pressure 10,282 Pa; shaft power 371.2 kW; equipped with a 400 kW/6 kV motor; impeller material: 16Mn; casing material: Q235. Small-to-medium-capacity configuration: 9-26 № 15.3D; flow rate approximately 107,600 m³/h; total pressure approximately 10,475 Pa; shaft power 432 kW; equipped with a 500 kW/10 kV motor.

Final equipment selection must be based on the flue gas and air resistance calculation report and the secondary air connection parameters provided by the boiler manufacturer. Due consideration should also be given to the long-term impact of wear, ash accumulation, and operational adjustment margins on fan performance.

Application Scenarios

In power plants, secondary air fans are primarily used for the secondary air supply systems of circulating fluidized bed (CFB) boilers, ranging from 130 t/h units up to 300 MW-class units and larger. Furthermore, these fans serve as critical equipment for combustion air distribution and low-NOx control in pulverized coal-fired boilers, biomass boilers, waste-to-energy (incineration) boilers, and the air supply systems of industrial captive power plants. For applications involving high dust concentrations, high corrosivity, or significant load fluctuations, it is recommended to provide details—such as the dust content of the medium, temperature ranges, and annual operating hours—during the inquiry phase. This ensures that the material selection, wear-resistance treatments, and control mechanisms are appropriately tailored to the specific operating conditions.

Technical Team

Our technical team has been deeply engaged in the fan industry for 30 years and possesses extensive technical expertise.

Quality Control

Our company s production and inspection processes adhere to the ISO 9001 quality management system.
ADDRESS

ADDRESS

Industrial Park, Nanjiao Town, Zhoucun District, Zibo City, China
EMAIL

EMAIL

sales@kaiyuefans.com
PHONE

PHONE

+86 15105330566

Get A Quote

We will reply to you within three hours of receiving your message.
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.
Leave a message
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.