The primary dust removal fan for a Basic Oxygen Furnace (BOF) is the core motive equipment within the flue gas purification and gas recovery system of a steelmaking plant. Its performance directly determines whether the BOF can maintain continuous, stable, and compliant smelting operations. During the oxygen-blowing process, the fan operates under demanding conditions—characterized by high temperatures, high dust concentrations, the presence of combustible gases, and periodic fluctuations. It provides the necessary negative pressure (suction) for the entire OG (Oxygen-blown Gas recovery) or LT (dry-type dust removal) system, forcing flue gas from the furnace mouth through cooling, dust removal, and switching equipment to facilitate dust extraction and the subsequent recovery or venting of the process gas.

Core Functions and System Role

The primary task of the BOF dust removal fan is to overcome the total system resistance—spanning the path from the furnace mouth through the evaporative cooling flue, evaporative cooler, and electrostatic precipitator (in dry-type systems) or scrubber (in wet-type systems), all the way to the switching station—while simultaneously maintaining a slight negative pressure at the furnace mouth to prevent the escape of flue gas.

In dry-type systems (LT process), the system resistance is relatively low; however, the fan must meet extremely stringent requirements for high-temperature tolerance, explosion-proofing, and leak-proof sealing.

In wet-type systems (OG process), the flue gas temperature drops significantly after scrubbing, but the system resistance increases substantially, requiring the fan to operate continuously under a much higher pressure head. Regardless of the process route, a fan failure necessitates the interruption of the smelting process—resulting in losses that far exceed the value of the equipment itself—which is why reliability is the primary criterion for equipment selection.

Fan Selection: Dry-type vs. Wet-type Processes

For dry-type dust removal systems, axial-flow fans are the standard choice. In these systems, the flue gas temperature is typically maintained between 160°C and 200°C (reaching up to 250°C in some cases). The medium consists of dust-laden BOF gas, necessitating strict adherence to explosion-proof standards and zero-leakage sealing requirements. For typical dry-type primary dust removal systems, the flow rate capacity of the fans ranges from approximately 130,000 m³/h to 450,000 m³/h, with a total pressure typically between 6 kPa and 10 kPa, and power ratings generally falling within the 315 kW to 1,400 kW range. In large-scale converter operations, a single axial-flow fan can handle a gas flow rate of up to 83 m³/s (approximately 298,800 m³/h) at a total pressure of 10,000 Pa, with a design rotational speed reaching up to 2,300 r/min.

Fans used in wet-type dust removal systems typically feature a dual-support centrifugal design. Although the flue gas is cooled and dedusted in a scrubbing tower—bringing its temperature down to around 65°C—the system resistance is significantly higher than that of dry-type systems, necessitating a higher pressure rise from the fan.

Typical fans for wet-type primary dust removal offer flow rates ranging from 2,000 m³/min to 4,000 m³/min (i.e., 120,000 m³/h to 240,000 m³/h) and can achieve a pressure rise of up to 28,500 Pa. These fans often utilize high-efficiency, energy-saving impellers with backward-curved blades and a horizontally split casing design, which allows the rotor to be lifted out for maintenance without disturbing the inlet and outlet connections.

Key Technical Design for Demanding Operating Conditions

High Wear Resistance and Corrosion Resistance

Iron oxide dust present in converter flue gas is highly abrasive, while wet-type operating conditions also involve corrosion from acidic condensates. Consequently, both the fan blades and the casing must exhibit high levels of wear and corrosion resistance. For dry-type axial-flow fans, the blades are typically constructed from materials such as 15MnV (or equivalent), with the entire impeller made from high-strength, wear-resistant material; the blade surfaces often undergo specialized wear-resistant treatment to extend the rotor's in-service lifespan. In wet-type centrifugal fans, high-strength, wear-resistant steel impellers—often featuring a backward-curved blade profile—are employed to maintain high efficiency while minimizing the rate of wear. Sealing and Explosion-Proof Systems
Converter gas contains carbon monoxide (CO), and the flue gas temperature in dry-type dust removal systems often falls near the explosive limit of the gas; therefore, sealing and explosion protection are the fundamental requirements of the design. High-performance fans for dry-type systems typically employ reliable nitrogen-based sealing—aiming for zero leakage—to completely prevent gas from escaping and air from infiltrating. Furthermore, these fans must remain free from surging under varying operating conditions, maintain stability during low-flow operation, and possess robust vibration resistance and explosion-relief capabilities. For wet-type fans, the focus of explosion protection shifts toward system-level CO dilution and interlock control, while the fan unit itself is designed with an emphasis on corrosion and scale resistance.

Variable-Frequency Speed ​​Control and Integration with Smelting Cycles

Converter steelmaking is a cyclical, intermittent process characterized by drastic fluctuations in flue gas volume and temperature during the oxygen-blowing, hot-metal charging, and tapping stages. Operating a fan at a constant speed during non-blowing periods results in significant, unnecessary power consumption. Modern primary dust-removal fans for converters utilize variable-frequency drives (VFDs); speed commands are derived directly from the PLC signals monitoring the converter’s smelting status, allowing the fan speed to automatically adjust according to the specific process stage.

Selecting a lower design speed (e.g., in the range of 980 r/min) in combination with variable-frequency operation allows the system to meet peak demand while reducing daily energy consumption and mitigating fatigue-related wear on bearings and impellers. Industry standards explicitly require that equipment selection calculations account for flue gas temperature corrections, the air volume needed for safe CO dilution, and instantaneous peak flow rates. Furthermore, variable-frequency speed control and intelligent interlock systems are mandated as essential measures for achieving energy efficiency and inherent safety.

Rotor Dynamics and Structural Reliability

Because a rotor failure in a primary dust-removal fan can lead to production downtime lasting weeks, the dynamic design must incorporate a substantial safety margin. Dry-type axial-flow fans utilize a dual-support rotor structure with forged, two-stage impellers; the blade pitch can be adjusted while the unit is stopped to accommodate changes in operating conditions. The main shaft must be constructed from a material at least equivalent to 35CrMo, and the first critical speed must be at least 30% higher than the design operating speed to fundamentally avoid resonance zones. The rotor’s dynamic balance is maintained at the G2.5 grade. In conjunction with online vibration and temperature monitoring instruments, this enables continuous surveillance of bearing conditions and the level of rotor imbalance. The lubrication system utilizes a centralized thin-oil station, with cooling provided through a combination of water and air cooling, ensuring that both oil and bearing temperatures remain within controlled limits, even in high-temperature environments.

Overview of Typical Performance Parameters

For axial-flow fans used in dry-type primary dust removal systems, the typical technical specifications are as follows: the medium handled is dust-laden converter gas; inlet flue gas temperatures range from 0°C to 250°C; gas flow rates span approximately 130,000 m³/h to 450,000 m³/h; and total pressure ranges from 6 kPa to 10 kPa (reaching up to 10,000 Pa for large-scale units). These units are paired with motors ranging from 315 kW to 1,400 kW, with design rotational speeds selected between 1,000 r/min and 2,300 r/min depending on the unit specifications. Noise levels are generally targeted at 85 dB(A) (measured 1 meter from the unit).

For centrifugal fans used in wet-type primary dust removal systems, typical parameters include: a flow rate of 2,000 m³/min to 4,000 m³/min, a pressure rise of approximately 28,500 Pa, and an operating temperature of around 65°C. Structurally, these units feature a dual-support design, a horizontally split casing, and high-efficiency impellers with backward-curved blades.

Key Considerations for Selection and System Integration

When selecting a fan for a converter’s primary dust removal system, relying solely on the converter’s nominal tonnage or estimated airflow is insufficient. Selection must be based on the converter’s flue gas volume and temperature curves, as well as a calculation of the total system resistance. It is critical to verify three dynamic factors: the instantaneous flow rate during the peak of the oxygen-blowing process, the adjustments to fan performance necessitated by flue gas temperature, and the additional airflow required to ensure the safe dilution of carbon monoxide (CO). For dry-type dust removal systems, the fan’s explosion-proof rating and the availability of a nitrogen-purging sealing system must be verified; for wet-type systems, the impact of high flue-gas humidity—following the scrubbing process—on impeller corrosion and dust accumulation must be assessed. At the system integration level, fan speed control must be interlocked with furnace-mouth micro-negative pressure regulation, the positioning of the movable exhaust hood, and the operation of the gas-switching station to ensure smooth transitions between the blowing, gas-recovery, and flaring phases.

Why Choose Our Primary Dust Removal Fans for Converters?

Our primary dust removal fans for converters are designed with a focus on two core priorities: high availability and full-lifecycle energy efficiency. Regarding availability, the blade materials and wear-resistant treatments are specifically tailored to the dust characteristics of converter off-gas. The rotors undergo rigorous critical-speed verification and G2.5-grade dynamic balancing; combined with zero-leakage nitrogen sealing and forced-feed lubrication, these features minimize the risk of unplanned downtime.

In terms of energy efficiency, our variable-frequency drive (VFD) system is deeply integrated with the converter’s PLC-controlled smelting cycle. The fan speed automatically decreases during non-blowing periods, effectively decoupling power consumption from the actual flue-gas load. Furthermore, the high total-pressure efficiency of our dry-type fan units ensures significantly lower long-term operating costs compared to older, less efficient models.

Whether you are developing a new primary dust removal system or upgrading existing fans for better efficiency, we provide comprehensive, integrated solutions—covering aerodynamic selection, explosion-proof sealing configurations, and interlock logic—customized to your converter capacity, process route (dry or wet), and specific on-site operating conditions.

Please contact our metallurgical fan technical team to obtain customized selection calculations and performance curves tailored to your converter’s operating parameters.

Technical Team

Our technical team has been deeply engaged in the fan industry for 30 years and possesses extensive technical expertise.

Quality Control

Our company s production and inspection processes adhere to the ISO 9001 quality management system.
ADDRESS

ADDRESS

Industrial Park, Nanjiao Town, Zhoucun District, Zibo City, China
EMAIL

EMAIL

sales@kaiyuefans.com
PHONE

PHONE

+86 15105330566

Get A Quote

We will reply to you within three hours of receiving your message.
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.
Leave a message
Name
company
Telephone
Email
Message Content
File Upload
Please upload your files; uploading is optional.